ADA-7000, VM-7100, VM-7200: Connecting the ADA-7000 to the VM-7000 Mixer

Tags: vm-7100,vm-7200,ada-7000

Note: To connect the VM-7200/7100 and the ADA-7000 via R-Bus, a VM-24E I/O Expansion Board (sold separately) must be installed in the VM processor.

1. With the power off to all devices, connect the VM-7200/7100 to the ADA-7000 with the R-Bus cable provided with ADA-7000.

2. Turn the power on the ADA-7000 first, then the VM-7200/7100 processor. Wait for the VM-7200/VM-7100 control status to change to green, then turn on the VM-C7200/C7100

3. Press CLOCK SOURCE on the ADA-7000 to R-Bus to set the sampling clock.

Set up the VM-7000 as follows:

4. Hold down SHIFT and press PROJECT on the VM-C7200/C7100 console.

5. Press the DOWN cursor to select the second row of the SYSTEM MENU.

6. Press F1 [DIGITAL I/O].

7. Press the DOWN cursor to select WORD CLOCK SOURCE.

8. Use the V1 knob to select INTERNAL.

9. Press F1 [SET] to confirm the setting.