AD-5 Acoustic Instrument Processor
BOSS
AD-5 OverviewDetailsSpecificationsImageGalleryBrochures FAQDownloadsOwner's ManualDemosUpdate Info
 
AD Conversion
21 bit AF Method*
 
DA Conversion
20 bit Input, 4 Times Oversampling Digital Filter + ΔΣMethod
 
Sampling Frequency
44.1 kHz
 
Nominal Input Level
INPUT: -10 dBu
INSERT RETURN: -10 dBu
 
Input Impedance
INPUT (PIEZO): 4.7 M ohms
INPUT (MAGNETIC): 1 M ohms
INSERT (RETURN): 100 k ohms
 
Nominal Output Level
OUTPUT: -10 dBu
OUTPUT (XLR): -10 dBu into 600 ohms
INSERT (SEND): -10 dBu
 
Output Impedance
OUTPUT: 2 k ohms
OUTPUT (XLR): 600 ohms
INSERT (SEND): 1 k ohms
 
Connectors
INPUT Jacks (PIEZO, MAGNETIC)
INSERT Jack (1/4 inch TRS Phone Type)
OUTPUT Jacks L(MONO), R
OUTPUT Connectors L, R (XLR-3-32 Type)
REMOTE Jack
AC Adaptor Jack
 
Power Supply
DC 9 V (Roland ACI or ACB-Series)
 
Current Draw
300 mA
 
Accessories
AC Adaptor (Roland ACI or ACB-Series)
 
Options
Foot Switch: FS-5U
Cord: Roland PCS-31 (1/4 inch TRS Phone Type - 1/4 inch Phone Type x2)
Size and Weight
 
Width
150 mm
5-15/16 inches
 
Depth
155 mm
6-1/8 inches
 
Height
65 mm
2-9/16 inches
 
Weight
1.0 kg
2 lbs. 4 oz.
* 0 dBu = 0.775 Vrms * AF method (Adaptive Focus method) This is a proprietary method from Roland that vastly improves the signal-to-noise (S/N) ratio of the A/D and D/A converters.